address:88 Ling Shan Road, Xukou, Wuzhong District, Suzhou City, Jiangsu Province, Unit 9A, 5th Floor, Liandong U Valley.
Telephone:0512-66559708
If you have any other questions, you can contact us by email
Contact Email
marketing@tronovo.com
M321A / M321C / M321E Type
The human body comprehensive tester is a personnel grounding tester, which accurately tests the wrist strap and anti-static shoes (foot ring) of ESD protection zone (EPA) personnel according to IEC 61340-5-1 (European standard), ANSI ESD S20.20 (American standard), SJ/T 10694 (electronic industry standard) and GJB3007A (military standard).
Features:
• Solid-state touch test buttons to keep tests accurate and extend the life of the tester
• Set the test range with the DIP code, and freely configure the control range of wristbands and electrostatic shoes
• Built-in electrostatic discharge function, which automatically discharges human static electricity during measurement
• Control signals for turnstiles or automatic doors, relays to control electronic door locks, lights, buzzers or air shower doors
• Background light reminds the indication function, locates the test button, and indicates the operation status
• Supports gloved measurements, allowing operators to test anti-static shoes while wearing gloves or finger covers
• Multi-scene installation, can be installed on turnstiles, ground vertical or wall mounting
• Adjustable alarm sound level, sound intensity is appropriate when alarming
• 3 sets of high-brightness LED status indicators to indicate high/pass/low resistance for wrist strap, left shoe, and right shoe
• Supports single and two-wire wrist strap measurements, and provides dual interfaces to improve the life of the plug and dial
• Test the pedal independently with both feet, and the left and right shoe tests are done at one time
Test scoping settingThe upper limit of the bracelet and the upper and lower limits of anti-static shoes can be set through the DIP switch on the left side of the device according to the control conditions. ANSI/ESD S20.20-2014 Certification Requirements IEC 61340-5-1-2016 Certification Requirements |
Practical, but not simple ...The panel is clearly designed and easy to read, showing low, high, and pass LEDs with large touch buttons to release static electricity and not easily damaged, and an audible alarm will sound when abnormal. |
Two-legged test boardAccording to the requirements of the static management code, each foot needs to be measured, and the pedal is designed independently of the feet, and the left shoe and right shoe are completely tested at one time. The two-foot pedal has a split foot pedal, a device that allows for independent verification of both feet at the same time. If many operators need to check their personnel grounding equipment, using a two-foot test pedal can save a lot of time. |
Single-wire wrist strap can be testedBefore entering the Electrostatic Protection Area (EPA), the anti-static wrist strap must be tested using a comprehensive body tester to ensure that it is working properly. Model TM7302 can test single wire wrist strap / double wire wrist strap |
No mechanical wear and durabilityThe test key uses an inner/outer metal conductor, and the test is started by holding down the finger to connect the inner/outer conductor. Solid-state test keys can be used to avoid mechanical damage. |
Wear gloves or finger sleeves for the testIf you wear gloves or finger covers, the test current cannot be started due to the high resistance, and an infrared induction grip is required. * When mode only, work shoe test is supported. |
Turnstile installationESD access control systems are compulsory, and employees must pass the ESD test before entering the workshop before they are allowed to enter. Supporting models: |
Wall-mountedIt can be conveniently fixed to the wall at the EPA workshop entry point. Supporting models: |
Bracket mountingThe steel bracket mounts directly to the pedals, giving you the freedom to mount the tester wherever you see fit. Supporting models: |
Dry node control signalsRelay terminals can be integrated with electronic door locks, turnstiles, lights, buzzers, etc. This would be an advantage if the company only wanted to let people in after they had passed the test. Dry Contact Terminals: |
Automatically discharges static electricity from the human bodyThe test table is groundedWhen the finger touches the test key, the static electricity of the human body can be released conductively. During the measurement, the fingers touch the test piece to realize the automatic release of human static electricity, and ensure that the static electricity value brought by employees entering the workshop is within a safe range. There is no need for a separate static elimination device. |
Model | M321 |
Single-wire wristband measurement | In the tank |
Dual-wire wristband measurements | - |
Work shoes measured | In the tank |
Wristband measurement range | lower limit:750KΩ Upper limit:10MΩ / 35MΩ(Optional) |
Work shoes measure range | lower limit:100KΩ / 750KΩ(Optional) upper limit:35MΩ / 100MΩ / 500MΩ / 1000MΩ(Optional) |
Power adapter | 100-240V AC转12V DC/2A |
The power cord is long | Approx. 1.5m |
Test voltage | 9V DC(Open Circuit) |
Test accuracy | ± 10% or ±20% (when 500M or 1GΩ thresholds are set) |
Relay maximum current | 1A@30VDC |
Operating ambient temperature | 5-30°C, 21°C~30°C (when setting 500M or 1GΩ threshold) |
Humidity of the working environment | 80% non-condensing max., less than 50% (500M or 1GΩ threshold set) |
Test table specifications | 160x100x32mm, weight: 0.3KG |
160x100x32mm, weight: 0.3KG | 400x420x35mm, weight: 5.3KG |
Net weight | The main body is about 6 kg (without stand) |
Warranty | One-year limited warranty |
There are currently no application cases available
There are currently no films available