Wrist Strap And Footwear Testers

Standing Human Body Integrated Tester

MP341A / MP341MP341E Type

The human body comprehensive tester is a personnel grounding tester, which accurately tests the wrist strap and anti-static shoes (foot ring) of ESD protection zone (EPA) personnel according to IEC 61340-5-1 (European standard), ANSI ESD S20.20 (American standard), SJ/T 10694 (electronic industry standard) and GJB3007A (military standard).

Features:
• Tests Operator’s Path-To-Ground; Wrist Strap Limits 750 kilohms to 10 megohms, Footwear Limits 750 kilohms to 1000 megohms
• Simultaneous Testing of Wrist Strap and Footwear in Less Than 3 Seconds
• Split Foot Plate for Testing Foot Grounders (or ESD Shoes)
• Relay for Use with Automatic Doors or Other Locking Systems
• Solid-State Test Switch with No Moving Parts
• Optional Stand
• Compatibility with ESD Glove Test Fixture
• Calibration Verification
• 3 sets of high-brightness LED status indicators to indicate high/pass/low resistance for wrist strap, left shoe, and right shoe
• Supports single and two-wire wrist strap measurements, and provides dual interfaces to improve the life of the plug and dial
• Test the pedal independently with both feet, and the left and right shoe tests are done at one time

Test scoping setting

The upper limit of the bracelet and the upper and lower limits of anti-static shoes can be set through the DIP switch on the left side of the device according to the control conditions.

ANSI/ESD S20.20-2014 Certification Requirements
EPA Electrostatic Discharge Protection Zone, Personnel Grounding RequirementsProduct Approval Requirements Limits: Human Shoes Ground System<1.0×109ohms; Test Method::ANSI/ESD STM97.1

IEC 61340-5-1-2016 Certification Requirements
EPA Electrostatic Discharge Protection Zone, Personnel Grounding Requirements Approved Requirements Limits: Human Shoes Ground System<1.0×108ohms; Test Method::IEC 61340-5-1

Practical, but not simple ...

The panel is clearly designed and easy to read, showing low, high, and pass LEDs with large touch buttons to release static electricity and not easily damaged, and an audible alarm will sound when abnormal.

Two-legged test board

According to the requirements of the static management code, each foot needs to be measured, and the pedal is designed independently of the feet, and the left shoe and right shoe are completely tested at one time.

The two-foot pedal has a split foot pedal, a device that allows for independent verification of both feet at the same time. If many operators need to check their personnel grounding equipment, using a two-foot test pedal can save a lot of time.

Dual-wire wrist straps can be tested

Before entering the electrostatic protection area (EPA), the anti-static wrist strap is tested using a comprehensive body tester to ensure that it is working properly. MP341 can   test single wire wrist strap / double wire wrist strap

No mechanical wear and durability

The test key uses an inner/outer metal conductor, and the test is started by holding down the finger to connect the inner/outer conductor. Solid-state test keys can be used to avoid mechanical damage.

Wear gloves or finger sleeves for the test

If you wear gloves or finger covers, the test current cannot be started due to the high resistance, and an infrared induction grip is required. * When mode only, work shoe test is supported.

Turnstile installation

ESD access control systems are compulsory, and employees must pass the ESD test before entering the workshop before they are allowed to enter.

Supporting models:
MP321E Single loop bracelet / access control function
MP341E Single and double loop bracelet / access control function
* Pictures shown are MP341E

Wall-mounted

It can be conveniently fixed to the wall at the EPA workshop entry point.

Supporting models:
MP321A single-loop bracelet / access control function is optional
MP341A single and double loop bracelet / access control function is optional
* The picture is shown as MP341A

Bracket mounting

The steel bracket mounts directly to the pedals, giving you the freedom to mount the tester wherever you see fit.

Companion model:
MP321C single-loop bracelet / access control function is optional
MP341C single and double loop bracelet / access control function option
* Pictures shown are MP341C

Dry node control signals

Relay terminals can be integrated with electronic door locks, turnstiles, lights, buzzers, etc. This would be an advantage if the company only wanted to let people in after they had passed the test.

Dry contact terminals
 Contacts 1 and 2 are normally open during standby; 2 and is normally closed. The status of each contact remains unchanged if the test fails. When the test is passed, 1 and 2 are closed; 2 and 3 are disconnected.
Relay Rated Current:
 When connecting the three-roller turnstile or other electronic locks, be careful that the external current does not exceed the rated range, otherwise the relay may burn out.

Automatically discharges static electricity from the human body

The test table is groundedWhen the finger touches the test key, the static electricity of the human body can be released conductively.

During the measurement, the fingers touch the test piece to realize the automatic release of human static electricity, and ensure that the static electricity value brought by employees entering the workshop is within a safe range. There is no need for a separate static elimination device.

ModelMP341
Single-wire wristband measurementIn the tank
Dual-wire wristband measurementsIn the tank
Work shoes measuredIn the tank  
Wristband measurement rangelower limit:750KΩ
Maximum: 10MΩ / 35MΩ (optional)
Work shoes measure rangelower limit:100KΩ / 750KΩ(Optional)
upper limit:35MΩ / 100MΩ / 500MΩ / 1000MΩ(Optional)
Power adapter100-240V AC转12V DC/2A
The power cord is longApprox. 1.5m
Test voltage9V DC(Open Circuit)
Test accuracy± 10% or ±20% (when 500M or 1GΩ thresholds are set)
Relay maximum current1A@30VDC
Operating ambient temperature5-30℃,21℃~30℃ (When 500M or 1GΩ thresholds are set)
Humidity of the working environment80% non-condensing max., less than 50% (500M or 1GΩ threshold set)
Test table specifications160x100x32mm, weight: 0.3KG
Foot pedal specifications400x420x35mm, weight: 5.3KG
Net weightThe main body is about 6 kg (without stand)
WarrantyOne-year limited warranty