Latex gloves are made of materials such as natural rubber or synthetic rubber, which are poorly conductive, and in the production process, latex gloves are prone to accumulate static electricity by rubbing against other objects.
In the latex glove coding process, static electricity elimination is very important, because static electricity may affect the quality and effect of coding. Using a static eliminator, you can place the static eliminator near the latex glove coding area during the coding process. The static eliminator will release ions that neutralize or cancel out the static charge on the surface of the glove. This prevents static electricity from interfering with the coding equipment and coding results.
Concern:
Rubber gloves in the production process, there is static electricity, spray code appeared to lack of pen or can not spray the words of the problem.
Solution:
1、Place the Eyewear Static Eliminator in front of the latex glove spray dock during the coding process.
2、Ensure that both the coding equipment and the latex gloves are connected to ground so that the static charge is directed to ground. This will effectively remove the static charge from the surface of the gloves and reduce static interference. Check the nozzles of the printer for clogging or damage, and replace or clean them promptly if necessary.
3、By taking the above measures, the problem of static electricity in the process of latex glove coding can be effectively eliminated to ensure the stability and consistency of coding quality and effect.
Picture the use of TRONOVO/E with high-power ion wind rod, ion rod installation location is very critical, not installed the closer to the glove the better, usually not ventilated recommended static eliminator distance from the product is about 4 ~ 5cm or so for the better, if ventilated recommended static eliminator distance from the product is about 5 ~ 20cm or so for the better.
Keywords: ee static eliminator, ion wind stick, de-staticizing stick, static eliminator, ee static eliminator, ee de-staticizing, ion wind knife, ion air knife, ion stick, industrial static eliminator, ion wind stick, de-staticizing stick, static eliminator, code de-staticifying device, code de-staticifying device, code de-staticifying device, code printer static eliminator manufacturers, static eliminator suppliers, static eliminator manufacturers, static electricity Static electricity eliminator wholesaler, static electricity eliminator price, static electricity eliminator brand